CD225-2J BLASTING MACHINE
|
Item Number: 14934
|
Click Here To View: Operations Manual
GENERAL INFORMATION
The REO Single Circuit Blasting Machines are of solid-state capacitor discharge design. They offer a wide variety of energy and voltage choices in a series of compact, lightweight, portable, water and corrosion resistant enclosures, and are designed to provide extended service under a variety of operation conditions.
SPECIFICATIONS:
Voltage: 225, Energy: 2 joules, Capacity: 35 single series
CHARACTERISTICS
Model
|
Volts
|
Energy
|
Capacity #1
|
Weight
[Shipping Weight]
|
Size
|
Power Source
(ALKALINE Batteries)
|
Single
Series#2
|
Parallel
Series#3
|
CD225-2J
|
225
|
2 Joules
|
35
|
Not recommended
|
0.8 lbs. (0.3 kg.)
[2 lbs. (1 kg.)]
|
4.1 x 2.2 x 3.6 in.
(10.5 x 5.6 x 9.0 cm.)
|
One 9 volt
Eveready 522
or equal
|
CD450-4J
|
450
|
4 joules
|
65
|
0.6 lbs. (0.3 kg.)
[2 lbs. (1 kg.)]
|
CD450A-22J
|
|
22 Joules
|
100
|
200#4
|
3.7 lbs. (1.7 kg.)
[5 lbs. (3 kg.)]
|
9.0 x 8.0 x 3.4 in.
(22.9 x 20.3 x 8.6 cm.)
|
Eight 1.5 volt "AA"
Cells Eveready
E91 or equal
|
CD450B-50J
|
|
50 Joules
|
105
|
500#5
|
5.2 lbs. (2.4 kg.)
[7 lbs. (3 kg.)]
|
10.3 x 7.3 x 4.1 in.
(26.2 x 18.5 x 10.2 cm.)
|
Eight 1.5 volt "C"
Cells Eveready
E93 or equal
|
CD600B-100J
|
600
|
100 Joules
|
140
|
1000#6
|
10.6 lbs (4.8 kg.)
[14 lbs. (7 kg.)]
|
9.5 x 8.1 x 6.2 in.
(24.1 x 20.6 x 15.7 cm.)
|
Twelve 1.5 volt "D"
Cells Eveready
E95 or equal
|
CD1000-9J
|
1000
|
9 Joules
|
145
|
Not
recommended
|
3.7 lbs. (1.7 kg.)
[5 lbs. (3 kg.)]
|
9.0 x 8.0 x 3.4 in.
(22.9 x 20.3 x 8.6 cm.)
|
Eight 1.5 volt "AA"
Cells Eveready
E91 or equal
|
CD1500-10J
|
1500
|
10 Joules
|
185
|
Notes:
1. 2 ohm EB detonators based on US standard detonator rating of 20 millijoules/ohm delivered in 5 milliseconds. Contact your powder company for recommendations. See SUITABILITY statement under OPERATION heading below.
2. 12 ohm maximum lead line.
3. 3 ohm maximum lead line.
4. 4 series of 50 2 ohm EB detonators.
5. 8 series of 63 2 ohm EB detonators.
6. 11 series of 91 2 ohm EB detonators.
|
FEATURES
|
Solid-state circuitry assures excellent reliability and service life.
|
|
Reliable.
|
|
Safety Interlock.
|
|
Sturdy construction for extended service life.
|
|
Rugged water and
|
|
Environmentally sealed to operate in most weather.
|
|
Heavy-duty, long life, ALKALINE batteries provide efficient and dependable power.
|
|
Fast battery change using
|
|
Temperature compensated circuits facilitate cold weather operaton.
|
OPERATION
Use of this equipment requires training in blasting techniques. Contact your powder company representative for training information.
This equipment must be operated in accordance with US Federal health and safety standards, state laws, rules and other applicable statutory provisions.
SUITABILITY: Properly trained and skilled personnel must determine suitability and safety factors of each blast.
IMPORTANT: Devices such as the REO Blasting Machine Energy Testers must be used to determine the energy output of each circuit prior to each blast.
Lead lines shall not be connected to the blasting machine until the circuit wiring has been verified by approved testers, the blast is ready to be fired and area safety is assured.
After the lead lines have been connected to the blasting machine, depress the CHARGE switch and hold it down. When the READY TO FIRE indicator lights, depress the FIRE switch while continuing to depress the CHARGE switch. Unless the CHARGE and FIRE switches are operated together, the machine will not fire.
CAUTION: WITH THIS MACHINE, AS WITH ALL BLASTING EQUIPMENT, STANDARD SAFETY RULES SHOULD BE FOLLOWED WHICH INCLUDE THESE: KEEP BLAST AREA CLEAR OF UNAUTHORIZED PERSONNEL, KEEP BODY AND HANDS AWAY FROM CONDUCTORS AND USE ONLY APPROVED TEST EQUIPMENT.
BATTERY LIFE
A lighted READY TO FIRE indicator confirms that the battery power was sufficient to charge the capacitors to the design voltage and the safety circuit is released.
The amount of time it takes for the READY TO FIRE indicator light to illuminate reflects remaining battery life. After months of firing cycles, a longer charge time will be required. However, regardless of battery condition, the full design voltage is present and the unit's safety circuits are released if the READY TO FIRE indicator is illuminated.
|
CD225-2J
|
Up to 450 charges
|
CD450-4J
|
Up to 350 charges
|
CD450A-22J
|
Up to 450 charges
|
CD450B-50J
|
Up to 475 charges
|
CD600B-100J
|
Up to 400 charges
|
CD1000-9J
|
Up to 600 charges
|
CD1500-10J
|
Up to 400 charges
|
SAFETY FEATURES
|
Blasting machine cannot be fired until the design voltage is verified and the safety circuit is released.
|
|
Case is sealed against moisture and dust, and is shock resistant.
|
|
Capacitors are shunted until the "Charge" switch is depressed.
|
|
The two terminals are shunted until the "Fire" switch is depressed.
|
|
Product Reviews
|
|