Your cart is empty.
* E.O.D. / Military / Law
* New Items
* Sale / Promotional Items
* Batteries
* Blasting Machines
* Blasting Meters & Testers
* Blasting Nonel Initiators
* Blasting Mats
* Books
* Cases & Pouches
* Flashlights
* Gifts: T-Shirts & Clocks
* GPS Systems
* Hole Plugs
* Knives
* Loading Equipment
* Locks-Padlocks / Pulse Code
* Lubricant - GIBBS
* Magazines/ Day & Cap Boxes
* Measuring / Surveying
* Placards - DOT
* Reels - Wire & Tapes
* Rock Breaker
* Safety Equipment
* Seismographs & Accesories
* Signs - Aluminum & VPO
* Sirens / Horns / Alarms
* Tools - Cutters & Crimpers
* Wire - Blasting
Email Address:
Request a Catalog
E-mail Us
Credit Application
Instantel Corporation
ISEE
French Cover Page
Spanish Cover Page
Indonesian Cover Page
Home
>
* Blasting Meters & Testers
>
GALVANOMETERS
>
Digital Galvanometer
Digital Galvanometer
<< Previous in GALVANOMETERS
Next in GALVANOMETERS >>
View Larger Image
Price:
$222.88
Item Number:
70341
Quantity:
Email this page to a friend
WATERPROOF DIGITAL
BLASTER'S GALVANOMETER
Mechanical:
Case Material: H.D. Urethane
Case Size: 3"W x 1.5"D x 4"H
7.6cm W x 3.81cm D x 10.13cm H
Weight: 9.8 oz. (0.278 kg)
Shipping Weight: 1 lb. (0.454 kg)
Electrical:
Power Source: 1 Ea. 9 Volt
Battery Voltage: 9.0 volt
Meter Range: 0 through 1999 OHMS
Operating Manual:
Section I - Mechanical
Case Material: Heavy Duty Urethane
Case Size: 3"W x 1.5"D x 4"H (7.6cm W x 3.81cm D x 10.13cm H)
Weight: 9.8 oz. (0.278 kg)
Type Circuitry: Digital
Power Source: 1 Ea. 9 Volt Battery
Section II - Operating Procedures
To test blasting circuit; simply touch to and hold both ends of circuit to
the contacts located on top of the unit and take resistance reading from
face of unit.
Do Not allow the contacts to become dead shorted for any extended period of
time against a conductive material as this will drain the Cell and could provide temporarily high readings.
Section III - Handling & Care
To maintain the proper functionality of your Scorpion Blaster's Galvanometer
please observe the following:
a. Avoid severe impact. The unit is impact resistant however
severe localized or blunt impact could crack and/or breach
the unit casing rendering the unit no longer waterproof.
or functional.
b. NEVER use your unit as a lever or impact device.
c. NEVER use your unit to test current. The unit is for measuring
electrical resistance ONLY.
d. NEVER USE OR ACCEPT READINGS FROM A DAMAGED OR QUESTIONABLE MACHINE.
For repair and servicing see Section V - Servicing.